pfc_propertyinitialize
|
|
Full name
|
pfc_u_tabpg_dwproperty_status.pfc_propertyinitialize
|
Access
|
public
|
Extend of
|
|
Return value
|
|
Prototype
|
event pfc_propertyinitialize()
|
Name
|
Datatype
|
li_rc
|
integer
|
ls_dataobject
|
string
|
event pfc_propertyinitialize;call super::pfc_propertyinitialize;//////////////////////////////////////////////////////////////////////////////
//
// Event: pfc_PropertyInitialize
//
// Arguments:
// anv_attrib The datawindow property attributes.
//
// Returns: Integer
// 1 = successful
// -1 = Error
//
// Description:
// Initializes the object.
//
//////////////////////////////////////////////////////////////////////////////
//
// Revision History
//
// Version
// 6.0 Initial version
//
//////////////////////////////////////////////////////////////////////////////
//
// Copyright © 1996-1997 Sybase, Inc. and its subsidiaries. All rights reserved.
// Any distribution of the PowerBuilder Foundation Classes (PFC)
// source code by other than Sybase, Inc. and its subsidiaries is prohibited.
//
//////////////////////////////////////////////////////////////////////////////
integer li_rc
string ls_dataobject
// Determine which Dataobject to try first.
If Len(Trim(inv_attrib.is_dataobjectstatus)) > 0 Then
ls_dataobject = Trim(inv_attrib.is_dataobjectstatus)
Else
ls_dataobject = idw_requestor.DataObject
End If
// Set/Validate the dataobject on the RequestorView used for the Primary view.
dw_requestorview.DataObject = ls_dataobject
li_rc = idw_requestor.ShareData ( dw_requestorview )
If li_rc <= 0 Then
// Try the Dataobject associated with the Requestor.
ls_dataobject = idw_requestor.DataObject
dw_requestorview.DataObject = ls_dataobject
li_rc = idw_requestor.ShareData ( dw_requestorview )
If li_rc <= 0 Then
Return -1
End If
End If
// Make all the columns available.
li_rc = dw_requestorview.Event pfc_propertyunprotect()
Return 1